Share:

IH RAMP IH 94EB-MI over LAND

Map 

Coordinates:
+43.02667, -87.92333
43°01'36" N, 87°55'24" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.

Facts 

Name:IH RAMP IH 94EB-MI over LAND
Structure number:B400285022A0000
Location:AT JCT IH 94-STH 59
Purpose:Carries highway overpass over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:64.6 ft. [19.7 m]
Total length:224.1 ft. [68.3 m]
Roadway width between curbs:30.8 ft. [9.4 m]
Deck width edge-to-edge:34.1 ft. [10.4 m]
Vertical clearance below bridge:15.4 ft. [4.7 m]
Skew angle:21°
Owner:State Highway Agency [01]
Year built:1968
Year reconstructed:1988
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:4
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

2010 Inspection 

Status:Open, no restriction [A]
Average daily traffic:3,500 [as of 2006]
Truck traffic:1% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:48.1 tons [43.7 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:75.8

2000 Inspection 

Status:Open, no restriction [A]
Average daily traffic:4,300 [as of 1979]
Deck condition:Good [7 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:48.1 tons [43.7 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:97.6

1992 Inspection 

Status:Open, no restriction [A]
Average daily traffic:4,300 [as of 1979]
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:48.5 tons [44.1 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:99.7
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]