Share:

IH RAMP LIN MEM DR over LAND

Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.

Facts 

Name:IH RAMP LIN MEM DR over LAND
Structure number:B400400005D0000
Location:1.3M E JCT IH 94 TO E
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:80.1 ft. [24.4 m]
Total length:233.9 ft. [71.3 m]
Roadway width between curbs:53.5 ft. [16.3 m]
Deck width edge-to-edge:57.4 ft. [17.5 m]
Vertical clearance above deck:16.1 ft. [4.9 m]
Owner:State Highway Agency [01]
Year built:1975
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:4
Main spans material:Concrete continuous [2]
Main spans design:Slab [01]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

2010 Inspection 

Status:Open, no restriction [A]
Average daily traffic:11,500 [as of 2006]
Truck traffic:1% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Good [7 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:69.5 tons [63.2 metric tons]
Inventory rating:41.0 tons [37.3 metric tons]
Sufficiency rating:76.0

2000 Inspection 

Status:Open, no restriction [A]
Average daily traffic:2,910 [as of 1979]
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Very Good [8 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:69.5 tons [63.2 metric tons]
Inventory rating:41.0 tons [37.3 metric tons]
Sufficiency rating:95.2

1992 Inspection 

Status:Open, no restriction [A]
Average daily traffic:2,910 [as of 1979]
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Very Good [8 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:69.3 tons [63.0 metric tons]
Inventory rating:40.6 tons [36.9 metric tons]
Sufficiency rating:95.1
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]