Share:

CTH T over SPRING VALLEY CREEK

Map 

Coordinates:
+43.47857, -90.80335
43°28'43" N, 90°48'12" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:CTH T over SPRING VALLEY CREEK
Structure number:P62095200000000
Location:2.3M N JCT USH 14
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:23.0 ft. [7.0 m]
Total length:23.6 ft. [7.2 m]
Roadway width between curbs:23.0 ft. [7.0 m]
Deck width edge-to-edge:23.6 ft. [7.2 m]
Skew angle:11°
Owner:County Highway Agency [02]
Year built:1963
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: October 2014 

Status:Open, no restriction [A]
Average daily traffic:200 [as of 2012]
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Basically intolerable requiring high priority of corrrective action [3]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:44.9 tons [40.8 metric tons]
Inventory rating:26.7 tons [24.3 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:63.8
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$135,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
October 201463.8Functionally obsoleteFairFairFair200
September 201269.5Functionally obsoleteFairFairFair200
September 201069.5Functionally obsoleteFairFairFair200
September 200869.5Functionally obsoleteFairFairFair200
September 200669.5Functionally obsoleteFairFairFair200
September 200469.5Functionally obsoleteFairFairFair200
September 200269.5Functionally obsoleteFairFairFair200
September 200074.5Not deficientSatisfactoryFairFair200
December 199870.4Functionally obsoleteSatisfactoryFairFair200
October 199665.8Functionally obsoleteSatisfactoryFairFair310
September 199476.0Functionally obsoleteSatisfactorySatisfactorySatisfactory310
December 199281.2Functionally obsoleteSatisfactorySatisfactorySatisfactory125
December 199081.2Functionally obsoleteSatisfactoryVery GoodSatisfactory125