Share:

SB I-695 over Anacostia River

Map 

Coordinates:
+38.87273, -76.99044
38°52'22" N, 76°59'26" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:SB I-695 over Anacostia River
Structure number:1416
Location:Anacostia River
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:233.9 ft. [71.3 m]
Total length:860.0 ft. [262.1 m]
Roadway width between curbs:60.0 ft. [18.3 m]
Deck width edge-to-edge:69.6 ft. [21.2 m]
Vertical clearance below bridge:33.5 ft. [10.2 m]
Owner:State Highway Agency [01]
Year built:2012
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:5
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: March 2015 

Status:Open, no restriction [A]
Average daily traffic:29,800 [as of 2004]
Truck traffic:3% of total traffic
Deck condition:Very Good [8 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Very Good [8 out of 9]
Structural appraisal:Equal to present desirable criteria [8]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:In place and functioning [2]
Scour condition:Bridge over "tidal" waters that has not been evaluated for scour, but considered low risk. [T]
Operating rating:56.1 tons [51.0 metric tons]
Inventory rating:43.6 tons [39.6 metric tons]
Sufficiency rating:98.0

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
March 201598.0Not deficientVery GoodVery GoodVery Good29800
February 201398.0Not deficientGoodVery GoodVery Good29800